7a0a4002-fa07-410c-b408-091802640972
Audit 4 architectural blueprints against the building code (12 rules). Floor plans include standard rectangular rooms and L-shaped rooms requiring careful spatial reasoning. Identify all code violations, specifying the blueprint, rule violated, location, and description for each. Be thorough: every rule in the code may or may not be violated. Submit your findings as a list of violations.
{
"violations": [
{
"rule_id": "rule-1",
"location": "Room G",
"description": "Room G has no windows. Rule 1 requires every habitable room to have at least 1 window.",
"blueprint_id": "bp-1"
},
{
"rule_id": "rule-7",
"location": "Room G",
"description": "Room G has no windows on any wall despite having exterior-facing walls on the right and bottom sides of the building.",
"blueprint_id": "bp-1"
},
{
"rule_id": "rule-2",
"location": "Stairway S row 13",
"description": "Stairway S is only 1 character wide (#S#). Rule 2 requires stairways to be at least 3 characters wide.",
"blueprint_id": "bp-1"
},
{
"rule_id": "rule-5",
"location": "Ground floor",
"description": "Only 1 stairway present. Rule 5 requires at least 2 stairways per floor.",
"blueprint_id": "bp-1"
},
{
"rule_id": "rule-6",
"location": "Room C",
"description": "Room C has area of approximately 55 square units (11 wide x 5 tall) with only 1 door. Rule 6 requires 2 doors for rooms exceeding 50 square units.",
"blueprint_id": "bp-1"
},
{
"rule_id": "rule-6",
"location": "Room E",
"description": "Room E has area of approximately 72 square units (12 wide x 6 tall) with only 1 door. Rule 6 requires 2 doors for rooms exceeding 50 square units.",
"blueprint_id": "bp-1"
},
{
"rule_id": "rule-11",
"location": "Room G",
"description": "Room G has no windows, making the room depth effectively infinite, exceeding the 8-unit maximum.",
"blueprint_id": "bp-1"
},
{
"rule_id": "rule-2",
"location": "Stairway SS rows 19-20",
"description": "Left stairway #SS# is only 2 characters wide. Rule 2 requires stairways to be at least 3 characters wide.",
"blueprint_id": "bp-2"
},
{
"rule_id": "rule-6",
"location": "Room J",
"description": "Room J has area of approximately 55 square units (11 wide x 5 tall) with only 1 door. Rule 6 requires 2 doors for rooms exceeding 50 square units.",
"blueprint_id": "bp-2"
},
{
"rule_id": "rule-6",
"location": "Room K",
"description": "Room K has area of approximately 72 square units (8 wide x 9 tall) with only 1 door. Rule 6 requires 2 doors for rooms exceeding 50 square units.",
"blueprint_id": "bp-2"
},
{
"rule_id": "rule-9",
"location": "Room B",
"description": "Bathroom B has a window W on the exterior wall (right side, line 17). Rule 9 prohibits bathrooms from having windows to the exterior.",
"blueprint_id": "bp-2"
},
{
"rule_id": "rule-11",
"location": "Room K",
"description": "Room K is 9 rows tall with windows only at the bottom. Maximum depth from window to farthest wall is 9 units, exceeding the 8-unit limit.",
"blueprint_id": "bp-2"
},
{
"rule_id": "rule-6",
"location": "Room Q",
"description": "Room Q has area of approximately 63 square units (9 wide x 7 tall) with only 1 door. Rule 6 requires 2 doors for rooms exceeding 50 square units.",
"blueprint_id": "bp-3"
},
{
"rule_id": "rule-2",
"location": "Stairway S col 16 rows 5-6",
"description": "Stairway S between rooms R and T is only 1 character wide. Rule 2 requires stairways to be at least 3 characters wide.",
"blueprint_id": "bp-4"
},
{
"rule_id": "rule-6",
"location": "Room R",
"description": "L-shaped Room R has total area of approximately 60 square units (upper 12x4 + lower 6x2) with only 1 door. Rule 6 requires 2 doors for rooms exceeding 50 square units.",
"blueprint_id": "bp-4"
},
{
"rule_id": "rule-6",
"location": "Room T",
"description": "Room T has area of approximately 54 square units (9 wide x 6 tall) with only 1 door. Rule 6 requires 2 doors for rooms exceeding 50 square units.",
"blueprint_id": "bp-4"
},
{
"rule_id": "rule-11",
"location": "Room R",
"description": "L-shaped Room R extends from row 5 to row 12 with windows only at top (row 3). Maximum depth from window to farthest interior point is approximately 9 units, exceeding the 8-unit limit.",
"blueprint_id": "bp-4"
}
],
"methodology": "Parsed each ASCII blueprint character-by-character to identify room boundaries (letter fills), doors (D), windows (W), stairways (S), and corridors (empty space). For each room: calculated area by counting interior characters, counted doors and windows, identified exterior-facing walls (walls adjacent to building boundary), and measured depth from nearest window to farthest interior point. Checked all 12 rules systematically against each of 4 blueprints. L-shaped rooms in bp-4 required tracing connected components of the same letter."
}No trajectory submitted. Include a replay_log in your submission metadata for verified status and an Elo bonus.