Audit 4 architectural blueprints against the building code (12 rules). Floor plans include standard rectangular rooms and L-shaped rooms requiring careful spatial reasoning. Identify all code violations, specifying the blueprint, rule violated, location, and description for each. Be thorough: every rule in the code may or may not be violated. Submit your findings as a list of violations.
{
"violations": [
{
"rule_id": "rule-1",
"location": "Room G",
"description": "Room G has no windows (W) at all, violating the requirement for habitable rooms to have at least 1 window.",
"blueprint_id": "bp-1"
},
{
"rule_id": "rule-5",
"location": "Entire floor",
"description": "Ground floor has only 1 stairway (S) area. Rule requires at least 2 stairways per floor.",
"blueprint_id": "bp-1"
},
{
"rule_id": "rule-2",
"location": "Stairway S at row 13",
"description": "The stairway is only 1 character wide, violating the 3-character minimum width requirement.",
"blueprint_id": "bp-1"
},
{
"rule_id": "rule-6",
"location": "Room E",
"description": "Room E has approximately 60 square units of interior space (12 wide x 5 tall) but only has 1 door (D), exceeding the 50 sq unit single-door maximum.",
"blueprint_id": "bp-1"
},
{
"rule_id": "rule-8",
"location": "Central corridor",
"description": "The central corridor section spans more than 15 units without any fire doors (F) to separate it.",
"blueprint_id": "bp-1"
},
{
"rule_id": "rule-9",
"location": "Room B (bathroom)",
"description": "Bathroom B has a window (W) on its exterior wall (right side, line 17), violating the rule that bathrooms must not have exterior windows.",
"blueprint_id": "bp-2"
},
{
"rule_id": "rule-2",
"location": "Stairway SS at rows 19-20",
"description": "The left stairway is only 2 characters wide (SS), below the 3-character minimum width.",
"blueprint_id": "bp-2"
},
{
"rule_id": "rule-6",
"location": "Room K",
"description": "Room K has approximately 72 square units of interior space (8 wide x 9 tall) but only has 1 door, exceeding the 50 sq unit single-door maximum.",
"blueprint_id": "bp-2"
},
{
"rule_id": "rule-6",
"location": "Room Q",
"description": "Room Q has approximately 54 square units of interior space (9 wide x 6 tall) but only has 1 door, exceeding the 50 sq unit single-door maximum.",
"blueprint_id": "bp-3"
},
{
"rule_id": "rule-6",
"location": "Room R (L-shaped)",
"description": "L-shaped room R has approximately 60 square units (12x4 + 6x2) but only has 1 door, exceeding the 50 sq unit single-door maximum.",
"blueprint_id": "bp-4"
},
{
"rule_id": "rule-6",
"location": "Room T",
"description": "Room T has approximately 54 square units of interior space (9 wide x 6 tall) but only has 1 door, exceeding the 50 sq unit single-door maximum.",
"blueprint_id": "bp-4"
},
{
"rule_id": "rule-8",
"location": "Corridor between rows 14-15",
"description": "Long corridor section spanning approximately 28 units with no fire doors (F) to break it up, exceeding the 15-unit maximum.",
"blueprint_id": "bp-4"
},
{
"rule_id": "rule-2",
"location": "S column at rows 5-6",
"description": "The S column between rooms R and T is only 1 character wide, below the 3-character minimum for stairways.",
"blueprint_id": "bp-4"
}
]